EN 10279 (UPE/UPN) and GB/T 706 have identical tolerances for critical dimensions, ensuring substitution compatibility:
| Dimension | Size Range | EN 10279 Tolerance | GB/T 706 Tolerance | Impact |
|---|---|---|---|---|
| Depth | ≤100 mm | ±1.0 mm | ±1.0 mm | No fit issues-channels align with brackets. |
| Depth | 101–200 mm | ±1.5 mm | ±1.5 mm | Consistent bending capacity. |
| Flange Width | ≤50 mm | ±0.8 mm | ±0.8 mm | Bolt holes align perfectly. |
| Flange Width | 51–100 mm | ±1.0 mm | ±1.0 mm | No bracket modifications needed. |
| Web Thickness | ≤5 mm | ±0.4 mm | ±0.4 mm | Identical shear capacity. |
| Length | 6–12 m | ±50 mm | ±50 mm | Easy on-site cutting. |
For example, a UPE 200 (depth 200 mm, tolerance ±1.5 mm) and GB C200x75x7 (same tolerance) fit the same beam brackets, with no gaps or misalignment. This alignment eliminates dimensional barriers to substitution.