How does round steel diameter affect its load-bearing capacity?

Sep 12, 2025

Leave a message

Diameter (Φ) directly determines load-bearing capacity, as it impacts cross-sectional area and section modulus:

 

1) Tensile/compressive capacity: Depends on cross-sectional area (A=π×Φ²/4)-Φ20 round steel (A=314mm²) can bear ~94kN (tensile) with Q235B (design strength 300MPa), while Φ30 (A=706mm²) bears ~212kN (2.25x higher);

2) Bending capacity: Relies on section modulus (W=π×Φ³/32)-Φ20 (W=785mm³) handles ~236N·m bending moment, Φ30 (W=3976mm³) handles ~1193N·m (5x higher);

3) Shear capacity: Related to area-Φ20 resists ~62.8kN shear, Φ30 resists ~141.2kN. Engineers select diameters based on load calculations (e.g., a 10kN axial load requires Φ≥21mm Q235B round steel).