What Is S355J0 HEA 240 H Beam?
S355J0 HEA 240 230×240×7.5×12 H Beam is a lightweight European wide-flange structural section made from S355J0 steel. Its actual height is 230 mm, flange width is 240 mm, web thickness is 7.5 mm, and flange thickness is 12 mm.
The standard section designation is HEA 240 or HE 240 A. With a theoretical weight of approximately 60.3 kg/m, the profile provides a useful balance between structural strength, bending stiffness and low self-weight. It is mainly selected for building beams, secondary columns, roof frames, platforms and prefabricated steel structures.


Dimensions of S355J0 HEA 240 Steel Profile
Unlike many HEB profiles, the nominal number "240" does not equal the actual height of the HEA 240 section. Its actual height is 230 mm, while the flange width is 240 mm. This distinction should be clearly stated in purchase orders.
| Technical item | HEA 240 specification |
|---|---|
| Standard designation | HEA 240 / HE 240 A |
| Actual dimensions | 230×240×7.5×12 mm |
| Steel grade | S355J0 |
| Material number | 1.0553 |
| Material standard | EN 10025-2 |
| Section standard | EN 10365 |
| Dimensional tolerance | EN 10034 |
| Surface standard | EN 10163-3 |
| Overall height, h | 230 mm |
| Flange width, b | 240 mm |
| Web thickness, tw | 7.5 mm |
| Flange thickness, tf | 12 mm |
| Root radius, r | Approx. 21 mm |
| Clear web depth, d | Approx. 164 mm |
| Cross-sectional area | Approx. 76.8 cm² |
| Theoretical weight | Approx. 60.3 kg/m |
| Surface area | Approx. 1.37 m²/m |
| Common lengths | 6 m and 12 m |
| Customized lengths | Available according to order |
The dimensions and weight correspond to the standard European HEA 240 section.
Performance of S355J0 HEA 240 230×240×7.5×12 H Beam
One advantage of this profile is that both its 7.5 mm web and 12 mm flange are within the thickness range up to 16 mm. Therefore, the full minimum yield-strength value of 355 MPa applies under EN 10025-2.
| Mechanical property | S355J0 requirement |
|---|---|
| Minimum yield strength, ReH | 355 MPa |
| Tensile strength, Rm | 470–630 MPa |
| Minimum elongation | 22% |
| Charpy V-notch impact energy | Minimum 27 J at 0°C |
| Elastic modulus | Approx. 210 GPa |
| Steel density | Approx. 7,850 kg/m³ |
This is different from larger H profiles with flanges thicker than 16 mm, for which the guaranteed minimum yield strength generally decreases to 345 MPa. The thinner HEA 240 section therefore combines the nominal S355 strength level with a comparatively low unit weight.
Chemical Composition of S355J0 HEA 240 H Profile Steel
The controlled carbon and manganese contents allow the S355J0 HEA 240 H Profile Steel to provide good strength and practical weldability for structural fabrication.
| Element | Maximum content (%) |
|---|---|
| Carbon, C | 0.20 |
| Silicon, Si | 0.55 |
| Manganese, Mn | 1.60 |
| Phosphorus, P | 0.030 |
| Sulfur, S | 0.030 |
| Nitrogen, N | 0.012 |
| Copper, Cu | 0.55 |
These values are general ladle-analysis limits. The actual chemical composition, carbon equivalent and mechanical-test results should be verified through the corresponding EN 10204 3.1 mill test certificate.
Does HEA 240 Provide Good Bending Stiffness?
The HEA 240 section places most of its steel in the two 240 mm-wide flanges. This material distribution provides useful bending stiffness without the additional weight of a heavier HEB profile.
| Section property | Approximate value |
|---|---|
| Strong-axis moment of inertia, Ix | 7,763 cm⁴ |
| Strong-axis elastic modulus, Wx | 675 cm³ |
| Strong-axis plastic modulus, Wpl,x | 745 cm³ |
| Weak-axis moment of inertia, Iy | 2,769 cm⁴ |
| Weak-axis elastic modulus, Wy | 231 cm³ |
| Weak-axis plastic modulus, Wpl,y | 352 cm³ |
| Strong-axis radius of gyration, ix | 10.10 cm |
| Weak-axis radius of gyration, iy | 6.00 cm |
The profile is efficient for moderate-load beams and frame members where reducing structural weight is important. However, these are geometric section properties rather than guaranteed load capacities. Span, restraint, buckling, connections and load combinations must be checked by the project engineer.
Weight of S355J0 HEA 240 H Beam
The theoretical weight of the S355J0 HEA 240 230×240×7.5×12 H Beam is approximately 60.3 kg/m.
| Beam length | Theoretical weight per piece |
|---|---|
| 6 m | Approx. 361.8 kg |
| 9 m | Approx. 542.7 kg |
| 12 m | Approx. 723.6 kg |
| 15 m | Approx. 904.5 kg |
| 18 m | Approx. 1,085.4 kg |
The total purchasing weight can be estimated as:
Total weight = 60.3 kg/m × length × quantity
For example, 30 pieces of 12 m HEA 240 beams have a theoretical total weight of approximately 21.71 tonnes. Actual shipping weight may vary slightly within permitted rolling tolerances.
HEA 240 or HEB 240: What Is the Difference?
HEA 240 and HEB 240 have different dimensions and weights even though both contain "240" in their designation.
| Comparison | HEA 240 | HEB 240 |
|---|---|---|
| Actual size | 230×240×7.5×12 mm | 240×240×10×17 mm |
| Cross-sectional area | Approx. 76.8 cm² | Approx. 106 cm² |
| Theoretical weight | Approx. 60.3 kg/m | Approx. 83.2 kg/m |
| Main feature | Lower self-weight | Thicker, heavier section |
| Typical selection | Moderate-load beams and frames | Heavier beams and columns |
HEA 240 is approximately 22.9 kg/m lighter than HEB 240. For a 12 m beam, the weight difference is approximately 274.8 kg per piece. This can materially affect total tonnage, lifting and transportation costs on a large project.
HEB 240 may be preferred when thicker flanges, higher section capacity or greater connection rigidity is required. The two profiles should not be substituted without engineering approval.
Fabrication and Surface Protection
The S355J0 HEA 240 Steel Profile can be supplied in standard mill lengths or processed according to structural drawings. Available fabrication includes fixed-length sawing, web and flange drilling, coping, notching, beveling, stiffener welding and base-plate or end-plate assembly.
The 240 mm-wide parallel flanges make bolted and welded connections relatively straightforward. Welding procedures should nevertheless be selected according to the actual carbon equivalent, joint restraint, welding consumables and ambient temperature.




S355J0 is conventional structural steel rather than weathering steel. For outdoor or humid-service structures, the beam should normally be protected by shot blasting and painting, hot-dip galvanizing or another project-approved coating system.
Inspection of S355J0 HEA 240 H Profile
Before shipment, the heat number marked on the S355J0 HEA 240 H Profile should be matched with the EN 10204 3.1 mill test certificate. The certificate should confirm the S355J0 grade, chemical composition, tensile results and 0°C impact performance.
Dimensional inspection should verify the correct 230 mm height, 240 mm flange width, 7.5 mm web and 12 mm flange. Length, straightness, flange squareness, surface condition and product marking should also be checked.




For fabricated beams, inspection can cover cut length, hole size, hole position, weld appearance and coating thickness. SGS, BV, TÜV or another nominated third party can be arranged when required.
Applications of S355J0 HEA 240 Wide Flange H Beam
The S355J0 HEA 240 wide flange H beam is suitable for floor beams, roof frames, mezzanine structures, industrial platforms, pipe racks, equipment supports, secondary columns and prefabricated building frames.
Its relatively low unit weight is beneficial where lifting capacity, foundation load or total structural tonnage must be controlled. The wide flange also provides sufficient space for common beam-to-column and beam-to-plate connections.
For heavily loaded primary columns, long unsupported spans or structures controlled by deflection and buckling, a heavier HEA or HEB section may be required. Final selection must follow the structural calculation.




We supply S355J0 HEA 240 230×240×7.5×12 H Beam in standard or customized lengths with EN 10204 3.1 material certification. Cutting, drilling, welding, blasting, painting, galvanizing and third-party inspection are available according to project requirements.

Request a Quote for S355J0 HEA 240 H Beam
For accurate pricing, please send the required length, number of pieces, total tonnage, fabrication drawings, coating requirements and destination port. We can provide specification confirmation, theoretical weight calculations, fabrication recommendations, loading plans, delivery time and FOB, CFR, CIF or DDP quotations.